I am replacing a fiberglass shower with a new tiled walk in. I found this vent pipe which breaks through the bottom plate. The water lines also are very close to the edge of the bottom plate.

I was going to install blocking all around but how do I handle this?

Should I attach furring strips to existing studs or perhaps use a 1" thick Kurdi board and hollow out the back side a bit.

I am planning on using the Schluter tray and I will need to dry pack around it.
Will the Kurdi board be enough support if I put it in first with no blocking?
Attached Images
 
__________________
Jim
JPG-WNY is offline   Reply With Quote
Sponsored Links
Old 02-05-2018, 09:21 AM   #2
John Bridge
Mudmeister
 
Join Date: Mar 2001
Location: Houston, Texas
Posts: 67,070
Send a message via AIM to John Bridge
Hi Jim,

It looks like thin furring strips will get you out past the vent pipe. And you don't need solid backing if you're using Kerdi-board. Just fur out the bottom plate the same as the studs, and bring the Kerdi-board all the way down to the subfloor. Then install your tray.
John Bridge is offline   Reply With Quote
Reply

Stonetooling.com   Tile-Assn.com   National Gypsum Permabase


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump

Similar Threads
Thread Thread Starter Forum Replies Last Post
Handling buried vent pipe in shower bed Mike_Qtile Tile Forum/Advice Board 16 01-10-2018 04:47 PM
Advice for dealing with interfering drain vent pipe nick9871 Tile Forum/Advice Board 16 09-18-2016 12:23 PM
Wall vent exhaust fan? TileArt1 Professionals' Hangout 11 06-27-2010 05:50 PM
Help-I may have screwed Durock to PVC vent pipe StarTRavel Tile Forum/Advice Board 15 03-02-2005 01:17 AM
Moving drains and vent pipe rob@netlumina.com Tile Forum/Advice Board 9 05-20-2004 07:57 PM


All times are GMT -6. The time now is 11:27 PM.


Sponsors

Powered by vBulletin® Version 3.7.4
Copyright ©2000 - 2018, Jelsoft Enterprises Ltd.
Copyright 2018 John Bridge & Associates, LLC