View Single Post
Unread 02-16-2021, 01:56 PM   #36
redlude97
Registered User
 
Join Date: Sep 2020
Posts: 60
Got the ditra heat cable installed over the long weekend and fixed a couple bumps in the floor by cutting out sections to scrape out high thinset spots.
Before going any further is there anything obviously wrong with my layout? I avoided under the floating vanity and where a cabinet will go, but after rechecking the install manual it said to avoid cable under a mat. Is a thin mat on top of the tile okay in front of the vanity and by the tub?

Finally, about to install the kerdiband using schluter all-set, do you mix to the thinner consistency used for setting the ditra mat or to the thicker consistency used for setting tile? If I prefill the mat what thickness should I use? wanting to mix up a full bag, install the kerdiband, and prefill the mat with the extra as others have done in some posts.
Attached Images
 
__________________
Hai
redlude97 is offline   Reply With Quote