Search: Posts Made By: eurob
Forum: Tile Forum/Advice Board Yesterday, 10:30 AM
Replies: 6
Views: 152
Posted By eurob
Chris, You are in the shallow end ........ Here...

Chris,
You are in the shallow end ........ Here it matters only what the manufacturer of the said product is recommending, without deviation from it.

However , if 8+9 allows it , for me is also...
Forum: Professionals' Hangout 08-05-2018, 03:12 PM
Replies: 15
Views: 1,780
Posted By eurob
I am sure there are few things which can be...

I am sure there are few things which can be improved -- benefiting the user -- .

I do know that blade is a must when porcelain is in play .

No deviation in 48'' on a DS 250 , as long as tile is...
Forum: Professionals' Hangout 07-26-2018, 09:36 AM
Replies: 33
Views: 1,389
Posted By eurob
And there is epoxy grout a+ :)

And there is epoxy grout a+ :)
Forum: Professionals' Hangout 07-25-2018, 08:21 AM
Replies: 21
Views: 1,120
Posted By eurob
For the purpose of discussion , I would assume --...

For the purpose of discussion , I would assume -- which should never happen with electricity -- that you are on a 120V circuit .

If the heating mat is in question and the '' running current '' is...
Forum: Professionals' Hangout 07-24-2018, 07:44 AM
Replies: 21
Views: 1,120
Posted By eurob
Just shocking ......... OP's posts = shocking:x:

Just shocking ......... OP's posts = shocking:x:
Forum: The Mud Box 07-21-2018, 04:09 PM
Replies: 2,410
Views: 296,773
Posted By eurob
https://www.youtube.com/watch?v=4a0Jk7RVjpc

https://www.youtube.com/watch?v=4a0Jk7RVjpc
Forum: Professionals' Hangout 07-21-2018, 05:06 AM
Replies: 21
Views: 1,120
Posted By eurob
So if you disconnect the mats , there is no more...

So if you disconnect the mats , there is no more shock while taking a shower ?
What is the voltage 120 or 240 ?
IS the discharge plumbing , including the SS drain , metal conductive ?

Grounding...
Forum: Professionals' Hangout 07-20-2018, 06:19 AM
Replies: 21
Views: 1,120
Posted By eurob
You are not allowed to have independent ground...

You are not allowed to have independent ground for the mat only.
Are there 2 different heating mats -- one for the shower And one for the bathroom -- ?
Is / Are it on 120V or 240V ?
Forum: Tile Forum/Advice Board 07-07-2018, 05:50 AM
Replies: 8
Views: 383
Posted By eurob
Code says you can't be more than 1/4 of an inch...

Code says you can't be more than 1/4 of an inch from finished wall -- tiles -- And front of the electrical box. So , the electrical box must be installed at least the thickness of the tile in front...
Forum: Professionals' Hangout 06-13-2018, 10:30 AM
Replies: 40
Views: 2,013
Posted By eurob
Don't know any premixed cement products which do...

Don't know any premixed cement products which do not harden when in contact with water or humidity......... Not a reason to not mix it properly, according with the designed intent.
Forum: Professionals' Hangout 06-09-2018, 07:14 PM
Replies: 40
Views: 2,013
Posted By eurob
I guess there is no shrinkage -- powder to solid...

I guess there is no shrinkage -- powder to solid state -- ..... and those mfg recommendations ..... well hidden in the waste container .

I will start using the dry powder from Laticrete to place...
Forum: Professionals' Hangout 04-28-2018, 10:20 AM
Replies: 15
Views: 1,780
Posted By eurob
I'll second the " It's all in the blade '' ...

I'll second the " It's all in the blade ''


201754

Didn't have the chance to try their -- Rubi -- new blade .
Forum: Tile Forum/Advice Board 04-01-2018, 10:18 AM
Replies: 35
Views: 2,264
Posted By eurob
http://www.tcnatile.com/faqs/56-movement-joint-spa...

http://www.tcnatile.com/faqs/56-movement-joint-spacing.html
Forum: Professionals' Hangout 03-31-2018, 05:02 PM
Replies: 30
Views: 2,673
Posted By eurob
Assuming that benefit of doubt -- prior to...

Assuming that benefit of doubt -- prior to covering with Ramboard , the epoxy color was consistent and uniform --has value , then the epoxy reacted with an unknown substance or it changed appearance...
Forum: Professionals' Hangout 03-30-2018, 11:55 AM
Replies: 30
Views: 2,673
Posted By eurob
So he did a better job on the cove base --...

So he did a better job on the cove base -- cleaning -- than on the floor ?
Did see epoxy react the opposite of cement grouts when residue or over watering happened.

Maybe an old batch of epoxy...
Forum: The Mud Box 02-17-2018, 05:48 PM
Replies: 15
Views: 928
Posted By eurob
Lots of outlets on that backsplash ..... near the...

Lots of outlets on that backsplash ..... near the sink as well :scratch:
Looks symmetrical thow:)
Forum: Professionals' Hangout 01-21-2018, 08:32 AM
Replies: 39
Views: 5,896
Posted By eurob
Favorite thin set for kerdi & ditra

Ultraflex RS / Ardex X7R
Forum: Professionals' Hangout 12-12-2017, 12:54 PM
Replies: 18
Views: 1,366
Posted By eurob
https://www.acousti-tech.com/Design/PDF/M-1324_Dem...

https://www.acousti-tech.com/Design/PDF/M-1324_Demystify%20the%20acoustics-2.pdf
Forum: Tile Forum/Advice Board 11-12-2017, 09:25 AM
Replies: 34
Views: 3,967
Posted By eurob
You said it '' I am a science teacher '' and ''...

You said it '' I am a science teacher '' and '' I'm hands-on about problem-solving and investigating '' , thus understand procedures and chemical '' incompatibilities '' -- too early contact with not...
Forum: The Mud Box 11-08-2017, 07:24 AM
Replies: 2,410
Views: 296,773
Posted By eurob
Is this efficient as advertised ? ...

Is this efficient as advertised ?


https://www.youtube.com/watch?v=kPk1THdJ7Gc
Forum: Tile Forum/Advice Board 11-07-2017, 05:13 PM
Replies: 21
Views: 1,799
Posted By eurob
Do you know how the hydroban was installed ? --...

Do you know how the hydroban was installed ? -- corners are wrapped and the hydroban flows/tied in continuously with the acrylic flange --

Have any pictures of the hydroban before tiles went on ?
Forum: Tile Forum/Advice Board 11-06-2017, 08:12 PM
Replies: 21
Views: 1,799
Posted By eurob
Hard to see -- from the pictures -- if water is...

Hard to see -- from the pictures -- if water is present behind the tiles . How did you determined there is water between the tiles and hydroban ?

The test with an independent ( could easily swap...
Forum: Professionals' Hangout 11-06-2017, 04:39 PM
Replies: 1
Views: 436
Posted By eurob
Thanks Mark :yo: Could you...

Thanks Mark :yo:




Could you elaborate on the low alkali portland cement statement and name some of the mortars which have low alkali content ? TIA
Forum: Tile Forum/Advice Board 11-06-2017, 04:36 PM
Replies: 21
Views: 1,799
Posted By eurob
Spot bonding -- not enough coverage -- method of...

Spot bonding -- not enough coverage -- method of installation could've been used , allowing water to '' freely '' accumulate.

Hairline cracks could tell something.

If you hit the back wall...
Forum: Professionals' Hangout 10-22-2017, 07:43 AM
Replies: 21,569
Views: 3,932,327
Posted By eurob
Perfect execution on the shower floor James :) ...

Perfect execution on the shower floor James :)
+1 the grout makes a huge difference


Had in mind this

198202

when mentioned about tile size . Thanks for loading your work up , it helped...